Founded 1989 · National High-Tech Enterprise · ISO9001 Certified
Home / Products & Services / Air Filters

Air Filters

G3 TO H14 · Full-efficiency air filtration for industrial ventilation, central air conditioning, cleanrooms and paint spray booths — engineered for clean air

↓
2

Product Series

AIR FILTER SERIES

Panel, bag, mini-pleat / paper separator / aluminum separator constructions; frames available in galvanized steel, aluminum, or 201/304/316 stainless steel.

ProductEfficiency ClassMedia / FrameKey ParametersTypical Applications
Primary (Coarse) Panel FilterG3 / G4Non-woven fabric / metal mesh; galvanized steel / aluminum frameLow resistance, high dust holding capacity, washable; standard type <70 ℃, high-temperature type for continuous 250–350 ℃ service (clean ovens)HVAC pre-filtration
Primary (Coarse) Activated Carbon FilterG3 / G4Activated carbon composite mediaRemoves odors and harmful gasesFresh air systems, kitchen exhaust
Medium Efficiency Bag FilterF5 – F9Non-woven fabric / fiberglass; galvanized steel frameLarge filtration area, long service life, high airflowHVAC medium-efficiency stage
HEPA Mini-Pleat FilterH11 – H14PP filter paper / fiberglass; aluminum frameEfficiency ≥99.95% @0.3μmCleanrooms, pharmaceutical workshops
HEPA Paper Separator FilterH11 – H14Fiberglass; aluminum / galvanized steel frameHigh structural strength, good temperature resistanceHigh-airflow clean systems
HEPA Aluminum Separator FilterH11 – H14Fiberglass; aluminum separatorHigh-temperature and humidity resistanceHigh-temperature, high-humidity clean environments
Paint Mist Pleated Paper FilterG3 / G4Pleated paper core; 201/304 stainless steel frameHigh paint mist capture efficiency, replaceable mediaPaint spray booths, coating lines
Panel Filter (Special)On requestNon-woven fabric / fiberglass; 201/304/316 stainless steel frameCorrosion-resistant frame, washableFood, chemical workshops

Selling point: Full G3–H14 efficiency coverage — one order covers primary + medium + HEPA; the paint mist pleated paper filter is a differentiated entry product for paint booth customers.

ⓘ

Selection Data

SELECTION DATA

Data from the company brochure: bag filter airflow–resistance table and HEPA filter size–efficiency table.

Bag Filters (G4–F9): Initial Resistance at Different Airflow Rates
Size W×H×T (mm)BagsAirflow / Initial ResistanceEfficiency Class
595×595×600825Pa at 2300 m³/h; 50Pa at 3500 m³/h; 85Pa at 4500 m³/hG4–F9
595×595×600625Pa at 2100 m³/h; 50Pa at 3200 m³/h; 85Pa at 4300 m³/hG4–F9
495×595×600625Pa at 2000 m³/h; 50Pa at 3000 m³/h; 85Pa at 4200 m³/hG4–F9
295×595×600325Pa at 1100 m³/h; 50Pa at 1800 m³/h; 85Pa at 2300 m³/hG4–F9
HEPA Filters (H10–H14): Size – Face Velocity – Efficiency Table
Size W×H×T (mm)Rated Face VelocityInitial Resistance at Different Face VelocitiesFiltration Efficiency
320×320×220400 m³/h
(box type)
—99%
484×484×220—99.9%
610×610×1501000 m³/h≤120Pa at 0.25 m/s; ≤220Pa at 0.5 m/s; ≤240Pa at 0.75 m/s99.99%
630×630×2201500 m³/h—99.999%
610×610×2922000 m³/h—99.999%

Notes: Media is ultra-fine fiberglass filter paper (U.S. H&V); frames available in galvanized steel / stainless steel, humidity resistance ≤99%RH; filter class H10–H14 (EN779), efficiency grades 99% / 99.9% / 99.99% / 99.999% (ASHRAE 52.1-1992). Custom sizes and airflow available.

HEPA Mini-Pleat Filters: Size–Airflow Table

Model (inches)Size mmAirflow m³/h (@0.45 m/s)
12×12305×305150
24×12610×305300
24×24610×610600
30×24762×610750
36×24915×610900
36×36915×9151350
48×241210×6101200
48×361210×9151800
48×481210×12102400

Mini-pleat filters: ultra-fine fiberglass media, separators aluminum or paper, aluminum or paper frame with protective mesh; efficiency covers medium F6–F9, sub-HEPA H10–H12 and HEPA H13–H14; service temperature <70 ℃. Resistance tolerance ±15%, custom sizes available.

High-Airflow HEPA Filters (W / V Type): Size–Airflow Table

Size W×H×T (mm)Rated Airflow m³/hEfficiency (@0.3μm)Media Cartridges
592×490×2901000>99.95%4
592×287×29215006
592×592×29221008
592×592×292270010
592×592×292340012

High-airflow HEPA: plastic-frame W / V configuration, synthetic or ultra-fine fiberglass media (U.S. H&V), filter class H10–H14 (EN779); used in hospital and cleanroom HVAC terminal supply to remove PM2.5 and fine particles — compact, lightweight and easy to install.

HEPA Separator Filters: Size–Airflow–Weight Table

Size W×H×T (mm)Rated Airflow m³/hInitial Resistance PaDust Holding Capacity gWeight kg
305×305×150250≤220350≈3.4
320×320×220350400≈4
305×610×150500600≈6.5
315×630×220750750≈7.7
480×480×2201000750≈8.5
610×610×1501000800≈11.5
726×484×2201400900≈10
915×610×1501500900≈13
630×630×2201500900≈13
968×484×22015001200≈15
1220×610×15020001200≈12.5
945×630×22022001400≈19
1260×630×22030001800≈23

Separator filters: internally pleated ultra-fine fiberglass media with paper / aluminum separators; frame galvanized steel / aluminum / stainless steel, polyurethane PU sealing; efficiency H10–H14, service temperature <70 ℃; for air purification at ambient temperature and pressure.

Patented: box-type air filter ZL202420966573.9 (granted 2024-12-20) · Full patent list →

Grade Guide

How Are G / F / H Grades Classified?

The wrong grade wastes money and misses cleanliness requirements — understand it at a glance.

G3 / G4 Primary (Coarse)

Captures coarse dust ≥5–10μm and protects downstream filters; washable with high dust holding capacity.

F5–F9 Medium Efficiency

Average counting efficiency 40–95% — the workhorse of HVAC medium stages and pre-filtration for paint spray booths.

H10–H14 HEPA

≥99.95% @0.3μm from H13 upward — final filtration for cleanrooms, pharmaceuticals, and electronics workshops.

Cost-Saving Rule of Thumb

Each higher grade costs roughly double; with good pre-filtration, HEPA service life can more than double.

Need filter selection or a quote?

Tell us your size, airflow, and cleanliness class — an engineer will respond within 1 working day.

Get a Quote → (+86) 186 6763 7331